No.MZU-1/7/10/Reg Dated Aizawl, the 7th June, 2010
NOTICE INVITING TENDERS
Mizoram University requires various Scientific instruments viz. Spectrometers, Flourimeter etc. for its Central Instrumentation Facility. Interested parties are requested to submit offers in a sealed two bid system to the undersigned by 30th July, 2010. ( Please see Annexure below for the complete list of instruments with specifications)
( Benjamina )
Registrar
No.MZU-1/7/10/Reg Dated Aizawl, the 7th June, 2010
REQUEST FOR PROPOSAL
Mizoram University required 500 KV to 1 MW Solar Generation for use by the University on internal grid. It is proposed to integrate the Solar panels with slanted roofs of the existing buildings and the upcoming buildings. Interested parties having expertise in this line are invited to submit their offers in a sealed two bid system (Technical & Commercial) to the undersigned latest by 9th August, 2010.
( Benjamina )
Registrar
Annexure (List of Specific Instruments )
S/N |
Instrument |
Specification |
|
1. |
Double Beam University-VIS-NIR Spectrophotometer |
Wavelength range : 175 – 3300 nm; Detector: PMT (University-VIS) & PbS (NIR); Variable slit width; Windows based software with user friendly operations; Peltier temperature controller; at least 8 place sample holder. Suitable for liquid and solid samples. |
|
2. |
Real-Time PCR |
Multiplex real-time PCR having peltier driven thermal blocks; suitable Detector; should be able to detect various types of fluorochromes/ radioisotopes. Minimum Four Colour Multiplexing or more. Long Life Span Light Source. More than gradient feature for optimization of PCR. Taqmen and Syber green Chemistry. Non PCR fluctuation shall be taken care of by internal reference guide. Fast reaction capability less than 40 minutes. |
|
3. |
PAM Fluorimeter |
Should be able to measure parameters such as F0, Fm, Fv/Fm and quantum yield. Suitable for leaf and cell suspension. |
|
4. |
Floor Standing Preparative Ultra Centrifuge |
1 lakh rpm and 7 lakh X g or more; temperature: 0 to 40oC or better. Fixed-angle, swing bucket and vertical rotors. |
|
5. |
Thermoluminescence Dosimeter Reader with Phosphors (PC controlled) |
Standard light source; Computer controlled Data acquisition & analysis software. Variable temperature controller/hot air annealing oven upto 500oC. Phosphors: Disks of Variable diameter & thickness. Detector : PMT along with Personal Computer System and accessories. |
|
6. |
Liquid Scintillation Counter |
Computer controlled multichannel analyzer for detecting small amounts of alpha, beta and gamma radioactivity and/or Luminescence; Suitable for counting all beta emitting isotopes. |
|
7. |
Transmission Electron Microscope (PC controlled) |
20-200 keV or more continuously variable energy, with ultra high resolution and contrast; equipped with hi-resolution CCD camera magnification 50 X -1.5 M X or better; Point t Point resolution 0.27 nm or better; Goniometer stage Eucentric, side entry; Tilting angle ± 70oC or better; Specimen movement X, Y2 mm (Manual, optionally fully computer controlled with specimen recall facility) Goniometer stage accepting variety of specimen holders including heating, cooling and low-background double tilt holders. Operation modes : Bright Field imaging & Dark Field imaging; Selected Area Electron diffraction including microdiffraction with rocking angle 1.5 to 20 mrad; EDS, SUTW detector, Cryotome; Cryo Low Dose System; 3-D imaging and Specimen Vitrification Device. |
|
8. |
Low Pressure Protein Purification System |
Inert biocompatible dual pump system capable of working in a pH range of 2.0 – 12.0; Flow rate 0.001 to 10ml/min or higher; Pressure 0-25Mpa(250bar). Equipped with rheodyne injector, variable loop sizes, and fraction collector. 16/32-bit PDA detector. Suitable for purifying different kinds of proteins. Compatible for monitoring fraction collector by absorbance, pH & Conductivity. |
|
9. |
Isoelectric focusing with 2-D gel electrophoresis unit |
Continuously variable Power supply 0-10000 volts and current 0-1.5mA or better. Temperature range -25 to + 60oC. Suitable for performing twin vertical gel electrophoresis; user friendly protein analysis software. |
|
10. |
CHNOS(Cl) Analyser (PC controlled) | Suitable for Solid and liquid samples; Furnance Temperature : adjustable up to 1000oC or more; Chlorine analysis facility. | |
11. |
|
Maximum condenser capacity of 5 liters with various drying accessories for small to large volumes. | |
12. |
Atomic Absorption Spectrometer (PC controlled) | With graphite furnance and double beam optical design; Hydride generator (As, Bi, Sb, Sn, Hg, Pb & Te); Lamp: Hollow cathode/EDL; Hollow cathode lamps for Cd, Sr, V, Co, Ni, Rb, Al, Ca, Cu, Fe, Mg & Zn; for other elements – lamps optional ; Detector : PMT/solid-state detector. | |
13. |
HR-Mass Spectrometer (PC controlled) |
ESI ionization source; Tandem Quad-TOF analyzer; coupling facility with liquid chromatograph. | |
14. |
Liquid Nitrogen Plant | Capacity : 5 lit/Hour or more. Nitrogen purity 99.99% |